Brand Name:
liangui
Model Number:
EI-150
The EI-150 automatic lamination stacking machine inserts E & I silicon steel laminations into transformer coil bobbins under PLC control. Built for 2000-5000 VA cores, it holds plus or minus 0.1 mm stacking accuracy at speeds up to 250 stacks per minute, producing the large, tightly compressed cores that power and distribution transformers depend on for their declared efficiency.
In a large transformer, no-load loss runs every hour of the unit's service life - often 15 to 20 years. That makes the core the most consequential part of the design: a stack with uneven compression or misaligned laminations raises no-load loss, and the finished unit can miss the efficiency class it was designed to meet. Because the penalty is paid continuously rather than once, small stacking defects compound into a large lifetime energy cost, and into a compliance risk when the transformer is tested against its declared values. The EI-150 controls what manual stacking cannot: identical placement of every lamination, identical compression force on every stack, and a counted, verifiable lamination quantity.
| Model | EI-150 |
| Stacking accuracy | ±0.1 mm |
| Positioning accuracy | ±0.02 mm |
| Stacking speed | Up to 250 stacks per minute |
| Applicable core range | 2000-5000 VA EI cores |
| Bobbin window width | Approx. 50 mm |
| Power supply | AC 200~250V, 50/60 Hz (customizable) |
| Power consumption | 30~60 W |
| Operating environment | 0°C to 45°C |
| Service air pressure | 0.4-0.65 MPa (dry & clean air) |
| Silicon steel thickness | Compatible with 0.3 mm, 0.35 mm, 0.5 mm |
| Applicable bobbin type | Cardboard or plastic bobbin |
| Control system | PLC with touch screen interface |
| Short circuit protection | AC220V overload protection + DC24V output short-circuit protection |
| Grounding | Dual grounding: 220V + 24V |
| Machine weight | 70 kg |
| Warranty | 12 months |
Sized for 2000-5000 VA cores, the EI-150 suits manufacturers of power and distribution transformers, industrial control and isolation transformers, inverter and UPS transformers, welding and rectifier transformers, and heavy-duty power supplies. Both cardboard and plastic bobbins are supported, and the machine works as a standalone station or inside a larger winding and assembly line.
When a finished transformer has to pass a no-load loss test against a declared efficiency class, the machine has to be checked against that test, not against a catalogue claim. These are the points we confirm in writing before the order and re-check after delivery:
| Verification point | What we confirm |
|---|---|
| Accuracy on your laminations | Stacking ±0.1 mm and positioning ±0.02 mm demonstrated on a first-off core made from your own EI-150 sheets. |
| Effect on no-load loss | Air gap stability, stack compression and lamination count confirmed as controlled variables, so the core behaves as designed when the unit is tested. |
| Window and fixture fit | Approximately 50 mm bobbin window confirmed against your EI-150 core set and bobbin drawing before the order is issued. |
| Bobbin compatibility | Cardboard and plastic bobbins checked against the fixture for flange and wall thickness before shipment. |
| Insulation coating protection | Handling checked on 0.3 / 0.35 / 0.5 mm sheet for coating damage that would show up later as eddy-current loss. |
| Electrical and safety package | AC220V overload protection, DC24V short-circuit protection, dual grounding, emergency stop - listed line by line in the quotation. |
| Site requirements | AC 200~250V 50/60 Hz, 30-60 W, dry air at 0.4-0.65 MPa, ambient 0-45 °C, 70 kg with no special foundation. |
| Support and references | CE-certified build, test run before shipment, delivery within 1-15 working days, professional after-sales technical support, 12-month warranty; equipment already supplied to GE Vernova, Eaton, CATL and Chint Electric in more than 20 countries. |
Our units are tested against a declared efficiency class. Can stacking really affect that?
Yes - no-load loss is set largely by the air gap and the compression inside the core. Uneven compression or misaligned laminations raise no-load loss, and the unit can miss its declared class. The EI-150 holds the air gap at ±0.1 mm and the compression uniform on every stack.
How does the machine keep the lamination count exact?
The PLC counts every sheet, so each core carries exactly the quantity its design specifies. A short or long stack is not passed silently into the varnish line.
Will thin 0.3 mm sheets survive handling?
Smooth lamination handling preserves the insulation coating on 0.3 mm, 0.35 mm and 0.5 mm silicon steel. Coating damage is what shows up later as eddy-current loss, so it is controlled at insertion rather than inspected after varnishing.
What happens on a misfeed with a core this size?
Automatic jam detection stops the cycle before material or tooling is damaged - on a 2000-5000 VA core that protects both the stack and the die set.
What are the site requirements?
AC 200~250V, 50/60 Hz (customizable), 30-60 W, dry clean air at 0.4-0.65 MPa, ambient 0-45 °C, dual grounding. At 70 kg the machine needs no special foundation.
Check the machine against your no-load loss test
Send us three things and we will confirm the fixture, the stacking parameters and the expected core behaviour, then return a quotation:
1. Your EI-150 lamination drawing, thickness and material grade 2. Lamination count, core height and bobbin type 3. The efficiency class and no-load loss limit your units are tested to
If your range also includes cores above 5000 VA or below 2000 VA, list them - we will say plainly whether one frame covers the range or whether a second model is the honest recommendation.
Factory-direct supply | CE certified | Test run before shipment | 12-month warranty | Delivery 1-15 working days | Professional after-sales technical support
Send your inquiry directly to us